Service - 210 JT40/JT40 All Terrain Operators Manual
Startup/10 Hour
Check Engine Coolant Level
Check coolant level, with engine cool and unit on
level ground at sight glass (1) of expansion tank
before startup and every 10 hours of operation.
Maintain coolant level at halfway point on sight
glass. If low, add approved coolant at fill (2).
Check Pipe Auto Lubricator Spray
Nozzle
Check pipe auto lubricator spray nozzle before
startup and every 10 hours of operation. Ensure
that nozzle is free of obstructions and operates
properly. Clean as needed.
To clean:
1. Rotate handle to the upward, or cleanout, position (A).
2. Operate pump until obstruction is flushed.
3. Rotate handle to the downward, or spray, position (B).
4. Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.
IMPORTANT: See “Approved Coolant” on
page 203 for information on approved coolants.
NOTICE: Ditch Witch
®
tool joint compound is
specially formulated to work with Ditch Witch pipe
lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 202 for more information.
NOTICE: If neoprene washer comes out during flushing, entire nozzle must be replaced.