STOP (S1) button: to switch from PARAMETER field to VALUE field.
OPEN (S2) / CLOSE (S3) buttons: to increase or decrease the size of the fields PARAMETER and VALUE
1. Put DIP switch 1 (S4) in ON position, PARAMETER digits start blinking
2. Select by OPEN (S2) / CLOSE (S3) buttons the number desired
3. Confirm by STOP (S1) button the PARAMETER selected. The VALUE digits start blinking
4. Select by OPEN (S2) / CLOSE (S3) buttons the number desired
5. To confirm the VALUE selected and return to PARAMETER field press STOP (S1) button
6. To leave the set-up mode, place the DIP1 in OFF.
i
NOTE: Some parameters require a further selection after pressing the STOP button (S1) as confirmation of the
desired value. For example, to operate the door during the limit switch set-up the display shows
RUN
.
The complete list of the parameters and values is available to the paragraph 13.
4.3 RESET PROCEDURE
The reset procedure allows to erase the settled data of the control unit memory and to return to the default program-
ming.
1. Put DIP 4 (S4) to ON position
2. Within 2 seconds press simultaneously the STOP (S1) / OPEN (S2) buttons
3. Display will shows
FAC
blinking and the control unit software version number
4. Put DIP 4 (S4) to OFF positio:
PARAMETER
digits
VALUE
digits
i
NOTE: when the control unit is power on, the display shows 4 digits about
the firmware version.