8
IP2358EN
If you need to disconnect the power cable and then to reconnect it or change the control unit wiring sequence, you
HAVE To connect the wires properly (following the diagram above), restoring the original configuration.
Take care to connect the ground wire to the X16 terminal.
1. ENCLOSURE INSTALLATION
For a correct installation:
• Install where the control unit can be protected from rain or adverse weather conditions.
• Mounting must be vertical.
• The surface has to be checked for flatness, slope and freedom from vibrations.
• Do not install in an area of potential risk of condensation.
• It is important that the door can be clearly seen from the position of the control through its travel.
• Install in an area not accessible to children or unauthorized persons.
• Do not perform any electrical connections before the enclosure installation is completely accomplished.
2. ELECTRICAL OPERATING INSTRUCTIONS
(Read carefully and respect the connection’s sequence).
IMPORTANT! All the connection operations must be performed only after the main power supply has been dis-
connected.
TURN OFF THE MAIN POWER SWITCH BEFORE ANY OTHER OPERATION!
When connecting control to mains supply a mains isolator switch (16A CEE - plug) according EN 12453 is required.
The supply disconnect device (main switch or CEE plug) must be installed between 0.6m and 1.7m above floor level.
2.1 CONTROL UNIT POWER SUPPLY
WARNING! The installation must include an automatic cut off switch with minimum distance between the con-
tacts of at least 3mm.
The control unit can be powered in two different modes: 400V~ 3-phase and 230V~ 3-phase.
The power supply of the motor and of the control unit must correspond.
WARNING: if you connect the wires differently from what is shown in the diagrams you can damage the motor
and the control unit and endanger the safety of the installer.
Here below shown the connection diagrams based on the selected power supply:
3x400VAC + N + PE 3x230VAC + PE
L1 L2 L3 N
PE PE
MAIN CEE PLUG
PE PE
X16
X1
BROWN
BLACK
GRAY
BLUE
PE PE
MAIN CEE PLUG
PE PE
WIRE JUMPER
X16
L1 L2 L3 N
X1
BROWN
BLACK
GRAY