ATTENTION: if it is NOT use a safety edge, see instruction paragraph 12.2 .
24
IP2358EN
17 > AUTO CLOSE FROM ½ OPEN
16 > PARTIAL OPENING
17:00
17:
0 1
01
No active
Active
16:
0 0
00
16:07
16:02
16:09
16:05
1 6 :12
16:01
16:08
16:04
16:1 1
16:03
1 6 :10
16:06
1 6 :13
No active
Partial opening active. Position controlled by mechanical micro switch
Partial opening active. Electronic limit on 50 % open position
Partial opening active. Electronic limit on 55 % open position
Partial opening active. Electronic limit on 60 % open position
Partial opening active. Electronic limit on 65 % open position
Partial opening active. Electronic limit on 70 % open position
Partial opening active. Electronic limit on 75 % open position
Partial opening active. Electronic limit on 50 % open position
Partial opening active. Electronic limit on 55 % open position
Partial opening active. Electronic limit on 60 % open position
Partial opening active. Electronic limit on 65 % open position
Partial opening active. Electronic limit on 70 % open position
Partial opening active. Electronic limit on 75 % open position
21 > SAFETY EDGE SELECTION
21:
0 1
01
21:03
21:02
21:04
PNE / DW air switch
8.2KΩ electrical (SOFA and SOFB series)
Optical
Special LP DW air switch
14. PARAMETER LIST
01 > OPERATION MODE
02 > REACTION – FAILURE ON PHOTOCELL OR SAFETY EDGE LIST
1 1 > SELECTION OF LIMITS
01:
0 1
01
01:03
01:02
01:04
Hold-to-run OPEN - Hold-to-run CLOSE
Impulse OPEN - Hold-to-run CLOSE
Impulse OPEN - Impulse CLOSE
Not in use
02:
0 0
00
02:01
Hold to run operation not possible when failure on photo or safety edge list
Hold to run possible when failure on photo or safety edge list
11:
0 0
00
11:05
11:06
Mechanical limits
Encoder - standard installation
Encoder - not standard installation
12 > TUNING OF ELECTRONIC LIMIT OPEN
See instructions (pg. 13)
13 > FINE TUNING OF ELECTRONIC LIMIT OPEN
See instructions (pg. 14)
14 > TUNING OF ELECTRONIC LIMIT CLOSE
See instructions (pg. 14)
15 > FINE TUNING OF ELECTRONIC LIMIT CLOSE
See instructions (pg. 15)
ATTENTION: set the limit switches (par. 5 or par. 6) before to adjust any parameter.
i
NOTE: bold values and underlined text correspond to the factory settings.