3.4 Technical data
Housing
Dimensions without cartridge
83 x 82 x 85 (B x H x T)
mm
Dimensions with 125ml cartridge
83 x 152 x 85 (B x H x T)
Dimensions with 250ml cartridge
83 x 175 x 85 (B x H x T)
Weight (without cartridge)
ca. 350 g
Mounting options backside: female thread M5 (2x)
bottom: female thread M5 (1x)
bottom: male thread M16 (1x)
max. torque mounting 3 Nm
Mounting position any, upright (preffered)
Material housing PA 6.6 GF30 / POM
Material outlet stainless steel
Operating temperature -15 ... +60 °C
Lubricant and hydraulics
Volume cartridge 125 or 250 cm³
Lubricant characteristics grease until NLGI class 2
Number of outlets 1
Hydraulic connection directly or via PA-tube
Number of lubrication points up to 8 in conjunction with aluminum progressi-
ve distributor*
max. pressure 50 (-10%/+15%) bar
Grease delivery per stroke 0,15 cm³
Electrics
Display LCD
Operating voltage (DC)
24 (20V...28V) V
Protection 0,75 (slow blow) A
Protection class IP 54
Current consumption
I
max
< 0,3 I
quiescent
< 0,025 A