If the FlexxPump 125 is in the Hour-Mode -h- or in the Empty-Time-Mode Et, the
output signal in the event of an error E1...E4 is always low level (0 V) via PIN 4 of the
electrical interface of the FlexxPump 125 (chapter 7.3).
If the Pulse-Control-Mode PUL is active at FlexxPump 125, i.e. FlexxPump 125
is commanded and controlled by an external controller (PLC), in the event of an error
the PLC will be informed about the error E1...E4 by different error messages as output
signals via PIN 4 of the electrical interface of the FlexxPump 125 (Chap. 8.3).
LCD Name Description Remedy
Error
E4
Fatal error
Disassemble the Flexx-
Pump 125 and return it to the
manufacturer together with
the lubricant cartridge and a
description of the fault.
A fatal error usually oc-
curs in the electronics of the
FlexxPump 125 and cannot be
repaired by you on site.
The address of the manufac-
turer can be found in chapter
I.II.