3.4 Technical data
Housing
Dimensions without housing 111 x 56,5 x 108 (W x H x D)
mm
Dimensions with housing for 250ml cartridge 111 x 165 x 108 (W x H x D)
Dimensions with housing for 400ml cartridge 111 x 198,5 x 108 (W x H x D)
Weight (without cartridge) appx. 1190 til 1450 (depeding on
version)
g
Mounting options holes for screw M6
Mounting position grease version: any position;
oil version: vertical
Material Zinc die-cast / PA 6.6 GF30 / POM
Material outlet Nickel-plated brass
Operating temperature -10 ... +60° °C
Lubricant and hydrauilcs
Cartridge volume 250 / 400 ml
Lubricant characteristics grease up to NLGI class 2
oil up to 30 000 cSt
Number of outlets 1 / 2 / 3 / 4
Hydraulic connection via PA-Tube
Number of lubrication points per outlet up to 10 in conjunction with aluminum
progressive distributor*
max. pressure 70 (-10%/+15%) bar
Steady state pressure 70 bar
Grease delivery per stroke 0.15 cm³
Electrics
Display nonexistant
Operating voltage 24 (20V...28V) V
Protection 0,75 (slow blow) A
Protection class IP 54
Current consumption I
max
< 0,3 I
quiescent
< 0,025 A
Further information on electrics can be found in Chap. 8!
* The stated value depends on the specic application and may vary considerably in individual