FlexxPump 250/400 DLS
User Manual
31
EN-
8.2.3 Control signal 8 seconds
The 8 second control signal triggers a single dispensing operation at pump unit 1 and
pump unit 2 when pump unit 2 is present. After a certain pause time, this control signal
can be repeated or another control signal can be sent.
The FlexxPump 250/400 DLS reacts only in a certain operating state to control signals
at PIN 2. The operating states are output by the FlexxPump 250/400 DLS via PIN 4 as
a high/low level and must be tapped and processed accordingly in the PLC.