SuperSigma2 QRM PMS V01.02.02 17-1-2020 Page 21 (58) ©2019 DMC GmbH Herten Germany
9.3 Menu 1 “Pump Adjustments”
Cal.
Ref.
Parameter
Calibrator
Text
Min.
adjust
Max.
adjust
Step size
Default
1
Acceleration delay
"Accel "
0,1 s
10 s
0,1 s
2,5 s
2
Deceleration delay
"Decel "
0,1 s
10 s
0,1 s
0,3 s
3
Creep speed
"Creep "
0,1 Hz
600 Hz
0 Hz
0 Hz
4
Creep speed Ramp
“CreepRmp”
0,1 s
10,0 s
0,1 s
2,5 s
5
Maximum pot speed 1
"Potmax1 "
0,1 Hz
600 Hz
0 Hz
0 Hz
6
Speed 2 demand
"Pspeed2 "
0,1 Hz
600 Hz
0 Hz
0 Hz
7
Speed 3 demand
"Pspeed3 "
0,1 Hz
600 Hz
0 Hz
0 Hz
8
Speed 4 demand
"Pspeed4 "
0,1 Hz
600 Hz
0 Hz
0 Hz
9
Speed 5 demand
"Pspeed5 "
0,1 Hz
600 Hz
0 Hz
0 Hz
10
Speed 6 demand
"Pspeed6 "
0,1 Hz
600 Hz
0 Hz
0 Hz
11
Minimum motor speed in cutback
conditions
"MinSpeed"
0,1 Hz
600 Hz
0 Hz
40 Hz
12
Acceleration for speed 6 demand (pwrStr)
"Paccel6 "
0,1 s
10 s
0,1 s
5 s
13
Power steer delay
"PStrDly "
0 s
50 s
0 s
5 s
14
Accelerator pot minimum
“AccMin”
0 V
10 V
0 V
0,2 V
15
Accelerator pot maximum
“AccMax”
0 V
10 V
0 V
4,6 V
16
Speed threshold to enter end of braking
“SpdThEbM”
0 %
50 %
0,1 %
5 %
17
Ramp time from SpdThEbMto zero
“SpdRmpTm”
0,1 s
10 s
0 s
1,5 s
18
Zero Speed threshold to end braking
“ZSpdTh”
0 %
10,0%
0,1 %
1,0 %

Table of Contents