EasyManuals Logo

DMC SuperSigma2 QRM User Manual

DMC SuperSigma2 QRM
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
SuperSigma2 QRM PMS V01.02.02 17-1-2020 Page 29 (58) ©2019 DMC GmbH Herten Germany
9.7 Menu 4 “PMS Motor Auto Tuning”
Cal.
Ref.
Parameter (Param.)
Calibrator
text
Min. adjust
Max.
adjust
Step
size
Default
1
Number of motor poles
Nmotpole
2
48
2
8
2
Sensor technology
1)
SensTech
0
2
1
0
3
Sensor supply voltage
SenSuppV
0
1
1
0
4
Number of sensor poles
NsnsPole
2
48
2
2
5
Reverse sensor reading
SpdRever
0
1
1
0
6
Reverse motor direction
MotorRev
0
1
1
0
7*
Battery Voltage
BattV AT
12. 0 V
Units
Umaxnom
1V
24V
8**
RMS motor current For tuning
I for AT
1 Arms
Units Imax
Arms
1 Arms
½ max
current
9*
Maximum RMS motor current
Imotmax
1 Arms
Units Imax
Arms
1 Arms
Max
current
10*
Back e.m.f. constant (KeV)
K emf
0.0 V/krpm
144.0
V/krpm
0.1
V/krpm
10.0
V/krpm
11*
Motor phase to phase inductance
L ph-ph
0 μH
3200.0 μH
1 μH
120 μH
12*
Maximum demagnetizing (Field
weakening) current
I demag
1 Arms
(disabled)
600 Arms
1 Arms
1 Arms
13*
Maximum Motor Frequency
Fmotmax
0.0 Hz
700.0 Hz
0.1 Hz
100.0 Hz
14
Start Auto-tuning
AutoTune
0
1
1
0
15
Recalculation after changing one of
the adjustments of this menu marked
with one star *
Recalcul
0
1
1
0
16
Sin/Cos Sensor Delay Angle at 100 Hz
SensDel
0,0 deg
15,0 deg
0,1 deg
3,6 deg
17
Auto Tuning Type:
0= Standard auto tuning (position
sensor tuning)
1= Full autotuning (position sensor +
Inductance and Ke mesurment)
ATuneType
0
1
1
0
(*) If a parameter with one star is changed, recalculation is required.
Recalculation is performed after setting the recalculation parameter to 1 and recycling the key.
(7**) The nominal current for autotuning “Inom” have to be set not higher than 30-40% of motor
continuous current. Higher values can overheat and or damage the motor.
(**) Changes to parameters with two stars are only considered when performing auto tuning after
recycling the key !
Note
1)
:sensorless options available on request. Refer to DMC.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMC SuperSigma2 QRM and is the answer not in the manual?

DMC SuperSigma2 QRM Specifications

General IconGeneral
BrandDMC
ModelSuperSigma2 QRM
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals