5.2 System status Menu
It is easily accessed from the main window of the PlayPad, by pressing once the ENTER key.
System Status
Description
Visualization on
Serial display
Resetting
The system is performing the reset procedure
O -
In service
The system is in normal operation mode
Inspection
The system is in inspection mode
OR
Temp. Operat.
The system is in temporary operations mode
P
Out of service
The system is out of service
Car Priority
The system is running in car priority mode (COP key switch activated)
Fire-fighters
The system is operating in Fire-fighters mode (various operations)
Emergency
The system is performing the emergency procedure
E
Drfit control
The system is performing the car drift control procedure
Fire Evacuation
The system is performing the fire evacuation
Water in the Pit
The system is performing the Water in pit evacuation
TILT Evacuation
The system is performing the Tilt evacuation
LOP Priority
The system is running in lop priority mode (LOP key switch activated)
BAGGAGE
The system is performing the BAGGAGE operation
SHUTTLE
The system is performing the SHUTTLE operation
RNO
The system is performing the RNO procedure
Upward oper.
The system is running upwards
Downward oper.
The system is running downwards
Re-levelling
The car is at floor level and is re-levelling
Still at floor
The car is at floor level, with no registered calls
High speed
The system is running in high speed mode
Low speed
The system is running in low speed mode
Door close
The door is completely closed
Door open
The door is opened (or opening/closing)
Car full load
The car has been fully loaded
Photocell A
The input relevant to the photocell entrance A is active
Photocell B
The input relevant to the photocell entrance B is active
BRA button
The input relevant to the open door button of entrance A is active
BRB button
The input relevant to the open door button of entrance B is active
Active fault
There is some active faults
Floor 0 12:30:56
Resetting..