ANNEX VI: Emergency/Rescue Manoeuvres
Unbalancing Rescue Operation’s
The operation must be performed by qualified personnel.
1. Open the Main Switch MDP
2. Turn Selector PME on EME position
3. Switch ON UPS module
4. Push BEB and Up buttons. NOTE: Door safety chain contacts are completely bypassed
Brakes will be powered, the Cabin should move for unbalance (direction according the load in the
cabin). In case of over speed (> 0,3 m/s) the Cabin will stop and require you to release the buttons
and press them again to restart.
When the Cabin reaches the floor (Green light “DOOR ZONE”) the controller automatically stops.
Release buttons BEB and direction
5. Press UP and DOWN buttons to open the doors
6. Bring people out of the Cabin
7. Turn the PME Selector to INSPECTION position and wait until the controller close the doors
8. Switch off the UPS module