Electrical emergency operation
The operation must be performed by qualified personnel.
1. Turn Selector PME on INSPECTION position;
2. Constantly press the "Up" or "Down" buttons. The car moves in the desired direction;
3. Press the "Up" or "Down" buttons simultaneously for 3 seconds to open the car doors.
To reset the system, position the PME selector on "NORMAL".
After activating the switch in "INSPECTION" mode, all car movements except those controlled by this
manoeuvre, and all floor calls, including remote devices, are excluded.
If you are in Electrical Emergency Maneuver mode, and a car roof or pit bottom switch is activated in
"INSPECTION" mode, the Maneuver is inhibited, and priority is given to the inspection push-button panels
in the Shaft