5.8 “Special Features” Menu
Table of Parameters
Parameter
Description
Navigation
Values
Default
value
Reset in
Direction of travel during reset procedure
◄►
Selection
Down;
Up
Down
Travelling limits
in inspection
Valid only for FAI/FAS positioning system.
Settings for the travelling limits during inspection mode.
If travelling is programmed beyond the limits, the controller does
not allow any movement beyond top/bottom floors.
◄►
Selection
Up to AGB/AGH;
Beyond AGB/AGH
Up to
AGB/AGH
Fire-fighters
(Refer to Annex XI - Fire operation programming procedure )
Type of fire-fighter operations (if present) and relevant
parameters (fire service access level and side, POM and CPOM
key contact type); choice of relevant applicable norm:
-) Norm NF P82-207 (France);
-) EN 81-72 (a): no car FF key switch;
-) EN 81-72 (b): with car FF key switch;
◄►
▲▼
Select field
Change value
Not present;
NF P82-207;
EN 81-72 (a);
EN 81-72 (b);
EN 81-73
DM 15/09/2005 (IT)
Not
present
Fire detection
Parameter for fire detection at floors.
- if the lift is at a different floor than the one where fire was
detected, all registered calls from/to this floor are cancelled;
- if the lift is at the floor where fire was detected, the controller
blocks door opening, closes doors (if open upon fire detection)
and sends the car to a safe floor
◄►
Selection
No;
Yes NO
Yes NC
No
Stop button
registration
The system registers the out of service mode (pressure of STOP
button).
It is also possible to set the delay to avoid simultaneous
movement in installations powered with a generator.
◄►
Selection
No;
Yes
No
EN 81-20
System setting according to EN 81-20
◄►
Selection
No;
Yes
No
Anti-nuisance
fault
Parameter for the detection of the anti-nuisance fault (number of
stops without photocell activation after which all car calls are
cancelled)
◄►
▲▼
Selection
No. calls
No; Yes
2 <-> 10
No
3
Out of service
floor
Floor for out of service.
Parking floor when HS input is enabled.
Increase Decrease
0 <-> Floor No.:
0
Automatic
return
Parameters for car automatic return at floor: Return floor and
Minimum waiting time before automatic return
◄►
▲▼
Select parameter
Change value
No
0 <-> Floor No.:
1 min <-> 60 min
No
0
15 min.
Return zones
Advanced settings for return at floor at planned hours / days:
-) Day (0 = everyday, 1 = monday … 7 = sunday);
-) Selected time interval (4 interval each day);
-) Return floor;
-) Start time;
-) End time (max time: 7h 45 min);
◄►
▲▼
Select parameter
Change value
R. zone timing
Timing for selected return zones
◄►
▲▼
Selection
Change Value
No; Yes
1 s <-> 120 s
No
60 s
Call erasing at
floor
Erasing all calls at floor where the car stops, with no control of
the direction (only for full collective installations)
◄►
Selection
No;
Yes
No
Drift control
(FR)
Drift control (France)
◄►
Selection
None; Traction
drive;
Drum machine