1835-065-D-5-17
28
3.2 Set-up Telephone Entry System for PC Programming
All DKS 1830 series telephone entry systems come standard with a 3000 memory chip installed on the board. The smaller
APB/memory chip no longer exists on the NEW 1830 board. The NEW 1830 can be re-programmed to work with with OLDER
existing 1830 entry systems.
The information below will assist you identifying chip specifications for older 1830 entry systems.
Before programming a NEW 1830 entry system to operate with existing older 1830 systems,
you must know the memory capacity and type of the EEPROM chips that have been installed
in the older units. This can be determined by inspecting the small chip that has a tag listing the
memory size on it and labeled APB if anti-pass back is enabled. The memory size determines the
number of residents, vendors, four-digit entry codes and device codes that can be stored in the
system. APB indicates that the chip set has anti-pass back capability. The table shows the valid
part numbers available with each memory level.
If you need to remove and replace chips, see Section 1.5 Memory Chip Replacement.
If you are going to re-program a NEW 1830 (less than 3000) to be used with existing OLDER
1830(s), Section 3.2.11 will need to be completed to MATCH the OLDER existing 1830(s).
3.1.3 System Memory Chip Identification
NC
NO
NO
RING
NC C
ON
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
12345 67891011121314
1
2
3
MIC
VOL
OFF
KEYPAD
321
321
321
MASTER
CODE
16AC16ACBAT1NO1NC1C2RY2CAZIMC5VDCIMDSPKRCOMMICPSWCGNDPHONE
Chip Locations
System Keypad
Chip Part Number
Standard APB
1835-150
1835-151
1835-152
1835-153
1835-154
1835-155
1835-156
1835-157
1835-140
1835-141
1835-142
1835-143
1835-144
1835-145
1835-146
1835-147
System
Memory
25
75
125
250
500
1000
2000
3000
Phone Number
Capacity
25
75
125
250
500
1000
2000
3000
Name
Capacity
25
75
125
250
500
1000
2000
3000
Entry Code
Capacity
25
75
125
250
500
1000
2000
3000
Device Code
Capacity
625
1875
3125
6250
8000
8000
8000
8000
Prior to using a PC to program this PC Programmable Telephone Entry System with the DoorKing Remote
Account Manager for Windows software, the programming steps in section 3.2.1 through 3.2.12 factory
settings MUST be reviewed or re-programmed if necessary (most factory settings are typically desired).
There is no need to re-program these settings unless you want to change them. For easy reference, refer
to the chart on page 33 that list the various programming functions and their factory default settings.
Section 3.2 can ONLY be programmed from the System Keypad. There is NO programming sequence
in the Remote Account Manager Software to program these features with.
This programming step sets the system MASTER CODE. The master code is the four-digit number REQUIRED to gain access to
the system memory. You need to know the master code prior to programming the system with the PC, or to perform ANY of
the programming functions on the following pages. It MUST be programmed in from the system keypad.
NO Factory setting - Each entry system’s master code MUST be unique.
See section 4.4 for more information about the master code switch.
Important Note: If you make a mistake while programming, press keys at the same time
to escape from programming no matter how much has been completed, then begin again at step 1.
1. Open the cabinet of the telephone entry system and turn the master code switch ON.
2. Enter a four-digit master code then press (beep).
3. Turn the master code switch OFF and close the cabinet.
3.2.1 Master Code
NC
NO
NO
RING
NC C
ON
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
12345 67891011121314
1
2
3
MIC
VOL
OFF
KEYPAD
321
321
321
MASTER
CODE
16AC16ACBAT1NO1NC1C2RY2CAZIMC
5VDCIMDSPKRCOMMICPSWCGNDPHONE
ON
OFF
MASTER
CODE
?
?
?
?
Important Note: There is no way of retrieving the master code after it has been
programmed in. If you forget it, you will have to program in a new one but all other
previously programmed information will remain intact.
7
8
9
4
5
6
1
2
3
0
OPER
WXYZ
TUV
PQRS
MNO
JKL
GHI
DEF
ABC
SP
CALL
Z
A
APB
30
00
1835
sn XX
THIS SIDE UP
0000010100010
0
OPER
TONE ON
TONE OFF
TONE ON
TONE OFF
Older
1830
System
ONLY