1835-065-D-5-17
32
STOP!! If the telephone entry system is to be programmed from a PC, NO other programming is needed at the system
itself. Refer to the Remote Account Manager for Windows Software help screens for additional programming information.
Continue with the remaining sections in this chapter if the telephone entry system will be programmed by any other method.
If the factory setting matches your needs, there is no reason to
reprogram that section.
Remember that advanced features like relay hold open time
zones, security levels, and elevator control functions can ONLY
be programmed from the Remote Account Manager Software.
If any of these advanced features are being used, DO NOT
proceed with any other programming steps in this manual.
SOFTWA
R
E
INS
T
A
LLED
SOFT
WARE
INSTALLED
PC’s only, NOT for use with MACs
SOFTWARE
IN
S
T
ALLE
D
The following programming sequence turns the “LIVE” Transaction viewing on your PC On or Off.
When turned ON, all transactions can be viewed “Real-Time” from your PC.
When turned OFF, the transaction buffer must be downloaded before viewing the transaction history log. The transaction buffer
stores the last 8000 events when downloaded.
Factory setting = 0 (OFF)
3.2.12 Turn LIVE Transaction Viewing On or Off
1. Press and enter your four-digit MASTER CODE (beep).
The LCD display on the 1835 and 1837 systems will read: view live? 0=NO 1=YES
2. Enter for YES - view live transactions or for NO - don’t view live transactions, then press (beep).
3. Press together to end this programming sequence (beeeeeep).
?
?
?
?
9
WXYZ
1
SP
1
SP
0
OPER
0
OPER
Download REMOTE ACCOUNT MANAGER Software FREE at:
http://www.doorking.com/telephone/telephone-accessories/software-remote-account-manager