Operation&MaintenanceManualTROUBLESHOOTING
TroubleshootingChart
ComplaintCauseCorrection
OutofFuel.Addcleanfuel.
CompressorOilT emp.too
high.
SeeComplaint#6.
EngineCoolantTemp.too
high.
Checkcoolantlevel.Iflow,
addcoolant.SeeComplaint
#3.
EngineOilPressuretoolow.SeeComplaint#4.
LooseorBrokenBelts.Tightenorreplacebeltset.
Loosewireconnections.
Checkwiresatswitches
andconnectorstondloose
connection.Makerepairs.
SeeElectronicService
Manual.
Lowfuellevelfault.Ifadequatefuelinthe
tank,checkfuellevel
senderdevice.Replace
ifdeterminedfaulty.See
ElectronicServiceManual.
Defectivesensor.Identifyandchecksensor.
Replaceifnecessary.See
ElectronicServiceManual.
Malfunctioningrelay.Identifyandcheckrelay.
Replaceifnecessary.See
ElectronicServiceManual.
Blownfuse.Identifyandreplacefuse.
SeeElectronicService
Manual.
Enginemalfunctioning.Seetroubleshootingin
Enginemanual.
1.Compressorhas
stoppedunexpectedly
Airendmalfunctioning.SeeComplaint#6.