ID Code type Authorizations
From 02 to
89
From 01 to
89
User Codes
If the Manager Code is not ac-
tivated via PC software.
- Opening the lock if necessary by activating
a Duress Alarm
Changing the own code
95 Courier Code - Opening the lock without OD / CW if neces-
sary with Duress Alarm
- Changing the own code
Setup Code - Opening the lock
5.2 Overview of commands
Command Authorization given to Function
P Every operator Changing the own code
P1 Master Reading-out audits
P2 Master (optionally executed by
the Manager)
Activating or deactivating OD / CW
P3 Master Activating users
P4 Enabling or disabling users
P5 Deleting users
P6 Query of code status
P7 Master (optionally executed by
the Manager)
Activating or deactivating Dual Mode
P8 Master Code Activating or deactivating Duress Alarm
P9 Acknowledging the tamper switch message
P0 Ermergency key Resetting the lock
P Re-assigning the Master Code
Functionality User Manual