Dormakaba Combi B 90 - Resetting the lock; Reconfiguring the lock via the PC software

Dormakaba Combi B 90
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ð The green light is on and the acoustic signal sounds twice.
6. Confirm the new Master Code 00XXXXXX.
7. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
8. Close the lock with the emergency key.
9. Mount the rotary knob.
10. Test the functioning of the Master Code with an opened secure storage unit
If the red light blinks 3 times and the acoustic signal sounds 3 times after the second code
entry, both entered codes do not match,
If the red light blinks 3 times and the acoustic signal sounds 3 times after the first code entry,
the ID is incorrect. During the change of the Master Code, the ID must always be '00'.
It is possible to cancel the procedure without change any time by pressing P twice.
Alternatively, the change of the Master Code is canceled if there is no code entry for 30
seconds or if the lock is closed with the emergency key during the change of the Master Code.
6.5.4 Resetting the lock (P0)
It is only possible to apply the configuration command while the lock is opened with the
emergency key. The functioning of the new Master Code must be checked by opening the lock
with an opened secure storage unit.
The configuration command is used to reset the lock. This procedure deletes all lock settings
(User Codes, Courier Code, Dual Mode, Duress Alarm, Opening Delay and Confirmation
Window), only the Master Code and the audit remain unchanged.
1. Open the lock with the emergency key.
2. Press P.
3. Press the ENTER key.
ð The green light blinks twice and stays on, the acoustic signal sounds twice.
4. Press P0.
5. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
6. Close the lock with the emergency key.
7. Mount the rotary knob.
It is possible to cancel the procedure any time by pressing P twice. Alternatively, the change is
canceled if there is no code entry for 30 seconds or if the lock is closed with the emergency
key.
6.5.5 Reconfiguring the lock via the PC software
After opening the lock with the emergency key and connecting the lock to the PC software, it
is possible to reconfigure the lock completely without knowing or changing the Master Code.
Only an audit entry is created.
For further information on this procedure, refer to the User Manual Combi B 90 PC software.
Operation User Manual
36 - 02/2022dormakaba Combi B 90 with metal input unit