1. Press P.
2. Enter the current Master Code 00XXXXXX.
00 = ID; X = previously configured 6-digit combination
3. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
4. Enter the new Master Code 00YYYYYY
00 = ID; Y = new 6-digit combination
5. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
6. Confirm the new Master Code by entering 00YYYYYY
7. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
6.2.2 Creating User Codes or the Courier Code (P3)
After the activation, the new saved code is valid and can be used. The new code must be
tested by opening the lock.
When activating a new operator, make sure that the new code is entered directly by the
operator on site. If the new code is not entered by the respective operator, but is assigned by
the master, the respective code must be replaced as soon as possible by a real personal code
from the respective operator.
Do not use personal data or data for your code which are easy to find out.
ID = 01 to 89 for User Codes or 95 for the Courier Code; X = freely selectable 6-digit
combination (0...9)
1. Press P.
2. Enter the valid Master Code 00XXXXXX.
3. Press the ENTER key.
ð The green light blinks twice and stays on, the acoustic signal sounds twice.
4. Press P3.
5. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
6. Enter a new code ID XXXXXX.
7. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
8. Confirm the new code with ID XXXXXX.
9. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
If both entered codes do not match (the first entry for the new code and the second entry for
code confirmation), the red light blinks 3 times and the acoustic signal sounds 3 times.
if the red light blinks 3 times and the acoustic signal sounds 3 times after the first code entry,
the code is already active.
OperationUser Manual
15- 02/2022 dormakaba Combi B 90 with metal input unit