EasyManua.ls Logo

Dormakaba Combi B 90 - Deleting User Codes or the Courier Code; Code status query

Dormakaba Combi B 90
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2.5 Deleting User Codes or the Courier Code (P5)
The deletion of the Master Code is not possible. But it is possible to re-assign the Master
Code by using the emergency key.
When deleting codes, the codes are irretrievably lost. To use these codes again, it is necessary
to activate these codes. Disabled codes can be deleted without previous enabling.
1. Press P.
2. Enter the valid Master Code 00XXXXXX.
00 = ID; X = valid 6-digit combination for the Master Code
3. Press the ENTER key.
ð The green light blinks twice and stays on, the acoustic signal sounds twice.
4. Press P5.
5. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
6. Enter the ID to be deleted.
ID = 01 to 89 for user or 95 for the courier
7. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
If the red light blinks 3 times and the acoustic signal sounds 3 times, either the ID has not
been activated or the ID is not available.
6.2.6 Code status query (P6)
There is a maximum of 30 sec. for each individual key press. If no key is pressed during these
30 sec., the electronics will shut down automatically.
It is possible to request the status of any code (active, disabled or inactive respectively
deleted) in this query. Neither the codes nor the statuses of the codes are changed by this
operation. It is possible to request the statuses of any number of IDs successively.
Code status Green light Red light Acoustic signal
active blinks once sounds once
active but disabled blinks once blinks once sounds once
deleted / inactive blinks once sounds once
1. Press P.
2. Enter the valid Master Code 00XXXXXX.
00 = ID; X = valid 6-digit combination for the Master Code
3. Press the ENTER key.
ð The green light blinks twice and stays on, the acoustic signal sounds twice.
4. Press P6.
OperationUser Manual
17- 02/2022 dormakaba Combi B 90 with metal input unit

Table of Contents

Related product manuals