6. Turn the actuating knob within 4 seconds through 90° clockwise to the stop.
If the red light blinks 3 times and the acoustic signal sounds 3 times after a code has been
entered, the code entry must be repeated. After 3 incorrect code entries the lock switches to
the lockout period.
There are 2 options to bypass a configured OD/CW by using the Courier Code:
After entering the Courier Code (ID 95) it is possible to bypass a configured OD and
open the lock immediately.
Bypassing a configured OD/CW if the Dual Mode function is activated. The Courier
Code must be the first entered code. After having entered the Courier Code, the
second code must be entered. Now it is possible to open the lock.
Bypassing a configured OD/CW by using the emergency key:
The Opening Delay can be bypassed by using the emergency key, but not deleted.
6.4.3 Opening with Dual Mode
1. Enter the first valid opening code ID XXXXXX.
ID = 00 to 89 or 95 respectively; X = configured 6-digit combination for the corresponding ID
2. Press the ENTER key.
ð The green light blinks twice and the acoustic signal sounds twice. Then for 30 sec. the
green light blinks once and the acoustic signal sounds once.
3. Enter the second valid opening code ID YYYYYY,
ID = 00 to 89 or 95; another opening code than the first one; Y = configured 6-digit
combination for the corresponding ID
4. Press the ENTER key.
5. The green light blinks twice and the acoustic signal sounds twice.
6. Turn the actuating knob within 4 seconds through 90° clockwise to the stop.
It is necessary that the operator IDs of both codes are different. The order of the code entry is
irrelevant.
If the red light blinks 3 times and the acoustic signal sounds 3 times, the second entered code
is incorrect or identical to the first code entry (identical IDs). In both cases the code entry
must be repeated.
After a total of 3 incorrect code entries the lock switches to the lockout period. No matter if
the first or the second code was entered incorrectly.