6.3 Configuration functions of the Manager Code
The Manager Code must be activated with the PC software (see User Manual Combi B 90 PC
software), otherwise the code with the ID 01 is a User Code.
For security reasons, the configuration and testing of the configuration must always be
performed with an opened secure storage unit. This is necessary to have always access to the
secure storage unit and the lock.
It is always possible to perform configurations individually without time delays (with
exception to blocking periods), even if the functions Dual Mode or OD/CW are activated. All
configuration processes can be canceled by pressing twice P. Alternatively, the configuration
will be canceled if no key has been pressed for 30 seconds.
6.3.1 Changing the Manager Code (P)
After changing the Manager Code, the old code is invalid. While the secure storage unit is
open, the new Manager Code must be checked if it is possible to open the lock with the new
code.
1. Press P.
2. Enter the current Manager Code 01XXXXXX.
01 = ID; X = previously configured combination of 6-digits
3. Press the ENTER key.
ð The green light blinks twice and stays on, the acoustic signal sounds twice.
4. Enter the new Manager Code 01YYYYYY.
01 = ID; Y = newly configured 6-digit combination
5. Press the ENTER key.
ð The green light is on and the acoustic signal sounds twice.
6. Confirm the new Manager Code by entering 01YYYYYY.
01 = ID; Y = newly configured 6-digit combination
7. Press the ENTER key.
ð The green light turns off and the acoustic signal sounds twice.
If the red light blinks 3 times and the acoustic signal sounds 3 times after entering the new
Manager Code, a wrong code was entered.
If the red light blinks 3 times and the acoustic signal sounds 3 times after having entered the
new code for confirmation, both new codes do not match.