42
ED900 09-2021DL4617-001
dormakaba ED900 Setup and Troubleshooting Instructions Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Status relay function, X terminals. Status relay is deactivated.

 - 
Status relay activated as soon as door reaches door "closed" position.
Status relay activated as soon as door reaches door "open" position.
Status relay activated when error codes are displayed on  digit operator display.
"Door closed and locked" activates status relay.
Status relay activated when information or error codes are displayed on  digit
operator display.
. Status relay activated when door is opened further than opening angle
parameter OA, set during learning cycle.
. Parameter OA value can only be changed using dormakaba handheld or by
performing another learning cycle.
Locking device output configuration;
output X, G (V) and input X, /a.
Reference Chapter .

 - 
Locking device output terminal X, G (V) is independent of Input X, /a.
. Locking device output terminal X, G (V) is turned on as soon as contact at
X, /a is opened..
. Terminal X, G V output is on for as long as contact at X, /a is open,
motor lock with a % duty factor is required.
. This function is not available for DCW motor locks.
Cycle counter.
. Total number of opening and closing cycles displayed is shown in increments of .
Display value, "", , cycles.
Display value, "", , cycles.
. Total number of cycles can be displayed on dormakaba handheld.
. A display value of "" means , cycles or greater.

 - 
* 
cycles
Delete error log.

 - 
No function.
. When "" entered, Error log is deleted.
. Parameter is then automatically reset to "".
Reset service interval display,
operator yellow LED.

0 - 1
No function.
. When "" entered:
Service cycle counter is reset to ,.
Service interval is reset to  months.
Yellow LED not illuminated.
. Parameter is then automatically reset to "".
. Values other than default values must be set using dormakaba USA, Inc.
handheld:
Maintenance interval
Maintenance cycles
A.. Driving parameters detail.