41
ED900 09-2021DL4617-001
dormakaba ED900 Setup and Troubleshooting Instructions Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Push & Go.
-
Off
. Parameter is activated.
. Automatic opening of door is started when door is manually moved ° out of the
closed position.
. Door close mode parameter hd must be set to "" (automatic) to enable this
function.
Mode switch type.
-
Internal, operator mounted Mode switch is active.
External mechanical Mode switch with contacts is connected to operator terminal
board. Internal Mode switch connector must be removed.
External DCW electronic Mode switch (EPS) is connected to operator terminal
board. Internal Mode switch connector must be removed.
Program switch control by TMS Soft control software.
. DCW electronic Mode switch (EPS) is installed, and operator is also connected
by the building management system to TMS Soft control software.
. When PS is set to , the Mode switch functions can be changed from
DCW (EPS) to TMS Soft..
Not used.
-
Not used.
Internal Mode switch, switch on delay.
-
Operator will perform function of new switch setting as soon as internal Mode
switch is moved.
. Operator will perform function of new switch setting after a delay of seconds
from when internal Mode switch is moved.
. This function is useful if user has to pass through door and its connected
detectors and sensors after Mode switch is set to new function.
Unlocking during business hours.
-
Door is always locked when it reaches closed position.
. In automatic mode, door will not lock when it reaches closed position. This
achieves faster door opening when system is equipped with motor driven locks.
. If an electric strike opener is used, it must be suitable for % continuous duty
factor to avoid possibility of damage.
A. Driving parameters detail.