44
ED900 09-2021DL4617-001
dormakaba ED900 Setup and Troubleshooting Instructions Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Power assist function.
. Force setting for Power assist function.
. Power assist function only available with hd parameter = , manual mode.
. ""; power assist function OFF; power assist function enabled for available values
greater than .
. Power assist function enabled when power assist activation angle hA reached.
. The greater the value of hF, the easier the door can be manually opened from power
assist activation angle hA.
. If power assist set too high, door can open automatically.
. Power assist function is not available
• If operator is switched off
• A smoke detector or emergency button has been triggered.
-
Additional power assist function support
from .
. Setting for additional power assist function support with door at .
. Power assist function only available with hd parameter = , manual mode.
. The greater the value of hS, the easier the door can be manually opened from the
closed position.
-
hS
A.. Upgrade card units codes.
-
Upgrade card not installed, function not available.
Upgrade card installed, function not activated.
Upgrade card installed, function activated.
Upgrade card has been removed, function no longer available.
Upgrade card fire protection
. Activate function by installing upgrade card, parameter value will automatically
change to (upgrade card function installed, fire protection function activated).
• Following activation, drive may be used as a electrically controlled hold-open system
according to EN , Building hardware-Electrically controlled hold-open systems
for fire/smoke door assemblies, or similar standards.
• Plug for terminal board X socket included with upgrade card.
Available
upgrade card
codes
(Para. A..)
, ,
Not used.
Not used.
Not used.
Not used.
A.. Driving parameters detail.