Half/Pack
®
Issued April 2018
Body Controller Software
Copyright 2018, Heil Environmental
Printed in the U.S.A.
Body Controller Software
125
A
None
N/A
Conditions Necessary to activate the circuit:
Condition
Function or
Component
Status
I/O Address
Status
A
Container Light Switch
Activated
CAN
ON
Note: With condition ‘A’ true, will activate the Container Light Output signal either from Street side or from Curb Side of the
dual control panel unit.
G10 Output Function (Option) – Curotto - Carry Can Light (In Cab Output %QX0.07)
This output function controls the Curotto - Carry Can Light output. Here CAN control is used to turn
ON/OFF the Curotto Can – Light, either from Street side or from the Curb side of a dual control panel unit.
Condition
Modifiable Parameters
Default Setting
A
None
N/A
Conditions Necessary to activate the circuit:
Condition
Function or Component
Status
I/O Address
Status
A
Can Light Switch
Activated
CAN
ON
Note: With condition ‘A’ true, the Curotto Can Lights will activate.
G11 Output Function – Auxiliary Backup Light Circuit (In Cab Output %QX128.13)
This circuit operates the Auxiliary Backup light circuit. Here Reverse and Switch control is used to turn
ON/OFF the Auxiliary Backup Light Circuit, either from Street side or from the Curb side of a dual control panel unit.
Condition
Modifiable Parameters
Default Setting
A
None
N/A
Conditions Necessary to activate the circuit:
Condition
Function or
Component
Status
I/O Address
Status
A
Reverse
Activated
CAN
ON
B
Auxiliary Light Switch
Activated
CAN
ON
Note: With condition ‘A’ or ‘B’ true, the Auxiliary Backup Light Output will activate.
4.09: Analog Input Functions
H01 Input Function – Packer Position (Analog Input %IW02)
This circuit measures the value of Packer Position.
Condition
Modifiable Parameters
Default Setting

Table of Contents