Half/Pack
®
Issued April 2018
Body Controller Software
Copyright 2018, Heil Environmental
Printed in the U.S.A.
Body Controller Software
159
Side Door Open (standard equipment)
If the side door was opened during a packing operation or the pump enable switch was turned ON or the Auxiliary
control for Packer Extend / Retract was enabled while the side door was open, the diagnostic message will be
displayed in the Insight display.
Insight Display Illustration:
Indication: A. Pump turns OFF unexpectedly.
B. Packer does not pack.
C. Pump will not turn ON.
Disabled Functions: Pump and all packer functions.
Fault Reset: Close the side door or repair faulty side door proximity switch.
Packer Extend PB held when fully extended (standard equipment)
If the Packer extend pushbutton was pressed (or was being pressed) or the Packer Auxiliary controls were activated
after the packer extended proximity switch is turned ON.
Insight Display Illustration: