Half/Pack
®
Issued April 2018
Body Controller Software
Copyright 2018, Heil Environmental
Printed in the U.S.A.
Body Controller Software
166
Arm Sensor Fault (standard equipment)
The Arm position value is greater than ‘1100’ or less than ‘-100’ during the operation then the diagnostic message will
be displayed in the Insight display. Also the value is not within the High or Low limit (do we need this statement as we
have given the Hi limit in 1
st
line)
Insight Display Illustration:
Indication: A. Arm Sensor faulty
B. Sensor failure ON
Disabled Functions: Forks will not raise above windshield.
Fault Reset: Check for the Faulty sensor or Sensor mounting position or calibrate the faulty sensor for
proper operation.
Arms Raised Interlock with Forks Untuck and Arms Raised Docked Interlock (standard
equipment)
If the arms have been raised when the top door is not fully open or the packer is not fully retracted and the Forks
Untuck position is ‘113’ and Arm Angle position is greater than ‘450’, the diagnostic message will be displayed in
the Insight display.
Insight Display Illustration:
Indication: A. Arms Overheight light ON.
B. Top Door Open light ON.
C. PTO-1 and PTO-2 pump Active signal ON.
Disabled Functions: Forks will not raise above windshield.
Fault Reset: Open the top door fully. Restart packer panel. Check top door and Packer retract prox.
switches for proper operation.
Low Oil Level Fault (standard equipment)
The hydraulic oil level has dropped below a safe operating level during operation then the diagnostic message will
be displayed in the Insight display.