Body Controller Software
171
Indication: A. The filter bypass pressure switch has been disconnected.
B. An open has occurred in the filter bypass input circuit.
C. The filter pressure switch has failed to open.
Disabled Functions: None.
Fault Reset: Cycle System Power Switch or Restore filter pressure switch input to CORTEX Controller.
Note: This fault is applicable on dry valve pump units only.
Temperature Sensor Fault (standard equipment)
The CORTEX32 Controller has received a signal from the Temperature sensor switch indicating that the Hydraulic
Oil temperature is out of specified limit i.e. Oil temperature value is less than ‘-100’ or exceeds ‘4000’. This is
recognized as a fault because Hydraulic Oil temperature should be within specified limit for proper operation of the
system.
Insight Display Illustration:
Indication: Oil Temperature Sensor fault