REMINDER: The recipient must first be configured under "Contacts" on page31.
Click Save when you complete the SMTP tab configuration.
6.1.8 Site Mapping (for Reconciliation/Autocalibration mode only)
A POS/FCC that uses the Gilbarco BCD Dispenser Interface Protocol must be used to communicate pump
sales. Configure the tank-to-nozzle mapping on this tab.
Field Description
Dispenser (POS system
settings)
This field identifies the index of the first pump (refer to the Gilbarco BCD Dispenser Interface
Protocol).
Select Index 0 if the first pump in the POS/FCC is identified as Pump 0.
Select Index 1 if the first pump in the POS/FCC is identified as Pump 1.
The word “Pump” refers to the Fueling Position as shown in the Gilbarco BCD Dispenser
Interface Protocol.
Nozzle (POS system
settings)
This field identifies the index of the first nozzle of the pump (refer to the Gilbarco BCD
Dispenser Interface Protocol).
Select Index 0 if the first nozzle in the POS/FCC is identified as Nozzle 0.
Select Index 1 if the first nozzle in the POS/FCC is identified as Nozzle 1.
The word “Nozzle” refers to the Meter Identifier as shown in the Gilbarco BCD Dispenser
Interface Protocol.
Total dispensers
Identifies the total number of pumps (Fueling Positions) that are connected to the tanks
monitored by the console
Max nozzles Identifies the maximum number of nozzles for each pump.
Click Save when you complete the top section of the Site mapping tab configuration.
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 29