32
Technical data
Dräger Testor 2100
Ambient conditions
During operation
Temperature +10 to +40
o
C
Air pressure 850 to 1400 mbar
Rel. humidity max. 70 %
During storage
Temperature –30 to +60
o
C
Air pressure 850 to 1400 mbar
Rel. humidity up to 100 %
Housing
Material ABS plastic
Dimensions (D x H x W)300 x 335 x 515 mm
Color blue / light gray
Weight approx. 4,9 kg
Compressed air supply 6 bar (4 bar to 9 bar),
breathing air quality
corresponding to EN 12 021
Compressed air connectionDräger PA plug-in nipple
Connection for lung demand valve
Inlet Dräger PA plug-in coupling
Outlet round thread Rd 40x1/7"
(internal thread)
according to EN 148-1
Test head rubber, inflatable and
detachable
Medium pressure manometer
Measuring range 0 bar to 16 bar
Scale division 0.5 bar
Class 1.6
Pressure relief valve integrated
Low pressure manometer (depending on version)
Measuring range –12 / 0 / 28 mbar
Scale division 1 mbar
Class 1.6
Measuring range –30 / 0 / 30 mbar
Scale division 0.5 mbar
Class 1.0
Timer LCD display
Preselectable 1 sec. to 99 min.
measurement period
After end of time acoustic signal
Battery coin cell 1.5 V - LR 44
Dräger Testor 3100
Ambient conditions
During operation
Temperature +10 to +45
o
C
Air pressure 850 to 1500 hPa
Rel. humidity 30 to 70 %
During storage
Temperature –10 to +60
o
C
Air pressure 850 to 1500 hPa
Rel. humidity 30 to 70 %
Measured value displays of the sensors
Low pressure ± 30 hPa/ ±1 % from the final
value
Medium pressure 2.5 MPa/ ±1 % from the final
value
High pressure 35 MPa/ ±1 % from the final
value
Operating characteristic values
Dimensions
Depth x height x width 300 x 335 x 515 mm
Weight approx. 5 kg
Operating voltage 5 V DC via USB