45
ECA Clutch
ECA Clutch In-Vehicle Resetting Procedure
1. Measure distance between release bearing and Low
Capacity Inertia Brake (LCIB):
• It is necessary to compress the LCIB to a solid
condition prior to measuring the distance
between the LCIB and the release bearing. A
screw driver can be used to compress the LCIB.
• With the LCIB compressed, proceed in measur-
ing the distance between the release bearing
and LCIB. If the measurement is not between
0.490" and 0.560" reset clutch. Go to Step 2.
2. Eaton Service Ranger Diagnostic Software is needed
to command the ECA to open the clutch.
Note: Keep the ECA Clutch Service Utility open. It will be
used again during this process.
LCIB
Correct Distance =
0.490" - 0.560"
Release
Beaing
Opening the ECA Clutch
2
Turn ignition
switch to on.
A
F
FO
NO
T
R
ATS
B
Plug 9-pin connector
into dash port.
3
Click on ServiceRanger icon
to launch program.
C
CAUTION
Ensure that hands are not inside the clutch
housing while opening or closing the clutch.