EasyManuals Logo

Eaton Powerware 9390 User Manual

Eaton Powerware 9390
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Table of Contents
ii
EATON Powerware
®
9390 UPS (100–160 kVA) Installation and Operation Manual S 164201554 Rev E powerware.com
4 Batteries 4-1...............................................................
4.1 Important Safety Instructions 4-1................................................
4.2 Installing Batteries 4-2.........................................................
4.3 Recycling the Used Battery or UPS 4-2...........................................
5 Installing a Remote Emergency Power-off Switch 5- 1..........................
6 Installing Options and Accessories 6-1........................................
6.1 Installing a Powerware Hot Sync CAN Bridge Card 6-1..............................
6.2 Installing Parallel System Control Wiring 6-2......................................
6.3 Installing a Remote Monitor Panel II 6-3..........................................
6.4 Installing a Relay Interface Module II 6 -4.........................................
6.5 Installing a Supervisory Contact Module II 6 -6.....................................
Section II Operation
7 Understanding UPS Operation 7-1...........................................
7.1 Looking Inside the UPS System 7-1..............................................
7.2 Single Module Reverse Transfer (RT) 7 -2.........................................
7.2.1 Single Module RT Modes 7 -2................................................
7.2.2 Normal Mode RT 7 -4.....................................................
7.2.3 Bypass Mode RT 7-6......................................................
7.2.4 Battery Mode RT 7-8.....................................................
7.3 Multiple Module Parallel System 7 -9.............................................
7.3.1 Multiple Module Parallel System Modes 7-10...................................
7.3.2 Normal Mode Parallel 7 -11.................................................
7.3.3 Bypass Mode Parallel 7-12..................................................
7.3.4 Battery Mode Parallel 7 -14.................................................
7.4 Functional Description 7-15.....................................................
7.4.1 Input Rectifier 7-15.........................................................
7.4.2 Inverter 7-15..............................................................
7.4.3 Battery Charger and Advanced Battery Management 7-15........................
7.4.4 Bypass 7-16...............................................................
7.4.5 Batteries 7-16..............................................................

Table of Contents

Other manuals for Eaton Powerware 9390

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Powerware 9390 and is the answer not in the manual?

Eaton Powerware 9390 Specifications

9390-40-N

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity40/36 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions519x1872x804 mm
weight UPS257 kg

9390-60-U

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity60/54 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions519x1872x804 mm
weight UPS313 kg

9390-80-N

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity80/72 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions519x1872x804 mm
weight UPS313 kg

9390-100-U

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity100/90 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions900x1872x804 mm
weight UPS480 kg

9390-120-N

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity120/108 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions900x1872x804 mm
weight UPS480/530 kg

9390-160-N

Battery IconBattery
battery capacity 55 Ah1270 kg
battery capacity 67 Ah1430 kg
battery capacity 125 Ah2350 kg
Power IconPower
capacity160/144 kVA/kW
nominal input voltage220/380, 230/400, 240/415 VAC
input voltage range-15%, +10% from nominal at 100% load
Operating Environment IconOperating Environment
operating temperature0°C to +40°C, +45°C with 7, 5% derating
storage temperature-15°C to +45°C
altitude< 1500 m
Weight and Dimensions IconWeight and Dimensions
dimensions900x1872x804 mm
weight UPS530 kg