Reasonably foreseeable incorrect use
According to the hazard analysis, the following points can lead to misuse:
n Operation with an open cover or without a cover
.
n Using the metering unit as a storage location for objects or tools.
n Non-compatible accessories.
n Line cross-sections that are too small.
n Incorrect ambient temperatures or media temperatures.
n Operation in potentially explosive areas.
n Use of unsuitable metering media.
Unauthorised modifications and spare parts
CAUTION!
Changes or modifications are not permitted without prior
, written permission
from Ecolab Engineering GmbH and shall result in the forfeiting of any and all
warranty entitlements. Original spare parts and accessories approved by the
manufacturer are designed to increase safety.
The use of other parts excludes the warranty for the resulting consequences.
Note that CE conformity expires if subsequent modifications are made.
2.3 Service life
If maintenance is conducted properly (visual inspection, functional testing, replacement of
parts, etc.), the life span of the Komponente is approximately 10 years.
Afterwards, a revision or a general overhaul may need to be done the manufacturer.
Ä
‘Manufacturer’ on page 11
2.4 Safety measures taken by the operator
NOTICE!
It is expressly up to the operator to train, monitor and instruct its operating and
maintenance personnel so that they comply with all of the necessary safety
measures.
The frequency of inspections and controls must be complied with and
documented.
WARNING!
Danger due to improperly installed system components
Improperly installed system components can result in personal injury and
damage to the system.
– Check that the system components provided (pipe joints, flanges) have
been installed correctly
.
– If assembly has not been performed by Customer Service or another
authorised party, check that all system components are made of the correct
materials and meet the requirements.
Safety