7.2.4 Descale the water distributor and spray nozzle
Personnel:
n
Service Personnel
Protective equipment:
n
Protective eyewear
n
Chemical resistant protective gloves
Material:
n
Ecolab Sidosil
®
Intensive Limescale Remover
WARNING!
Injuries from uncontrolled chemical spills
Uncontrolled chemical spills can cause serious injuries.
Use the personal protective equipment (PPE) specified in the safety data sheet
for the chemical products.
Requirements:
n Angle valve for water supply closed.
n Front hatch open.
Ä
Chapter 7.2.2 ‘Opening the front hatch’ on page 38
n Product cylinder is removed.
Ä
Chapter 7.2.3 ‘Remove the product cylinder’
on page 39
Fig. 13: Remove the water distributor and spray nozzle
"Bypass water" connection
"Spray nozzle" connection
1. Put some Sidosil ®
Intensive Rinse Aid in a cup or dish.
The liquid should completely cover the spray nozzle.
2.
Unthread the button
from the tab on the water distributor
and remove it.
3.
Disconnect the "bypass water"
and "spray nozzle"
connections from the water
distributor and remove it.
4.
Unscrew the spray nozzle
from the water distributor.
5. Dip the spray nozzle into the limescale remover and let it soak in for two minutes.
6. Rinse the spray nozzle thoroughly with clean water
.
Servicing and maintenance
41 MAN054128 Ver. 01-06.2024