7.2.5 Remove the double check valve
Personnel:
n
Service Personnel
Protective equipment:
n
Protective eyewear
n
Chemical resistant protective gloves
Requirements:
n Angle valve for water supply closed.
n Front hatch open.
Ä
Chapter 7.2.2 ‘Opening the front hatch’ on page 38
n Product cylinder is removed.
Ä
Chapter 7.2.3 ‘Remove the product cylinder’
on page 39
1
1
2
3
Fig. 16: Remove the double check valve
1
Plug-in coupling
2
Clean water pipe
3
Double check valve
1.
Press the retaining rings onto the plug-in couplings
1
and disconnect the clean
water pipes
2
in the direction of the arrow.
2.
Remove the double check valve
3
with its connecting parts from the unit.