5.2 Hydraulic installation
Connecting the internal water supply
Personnel:
n
Service Personnel
n
Qualified employee
Protective equipment:
n
Protective gloves
n
Safety shoes
n
Protective eyewear
Material:
n
Plastic tube with 3/8-inch outer diameter
n
Shut-of
f valve T-piece 15mm x 15mm x 3/8-inch pipe
n
Adapter 3/8-thread x 3/8-inch tube
Connect the appliance to the hot water supply as described below.
Requirements
n The unit is mounted in accordance with the regulations.
n The water supply line is shut of
f.
CAUTION!
Damage to the unit if the permissible water pressure is exceeded
– Always observe the max. permissible water pressures and temperatures
(see
Ä
Section Technical data on page 50 ).
If necessary, fit a pressure reducer and/or mixing valve upstream.
– The connection for the water supply (feed line) must be located behind a
shut-off cock (angle valve).
Assembly and connection
29 MAN054128 Ver. 01-06.2024