6 Commissioning / operation
6.1
Initial start-up
Personnel:
n
Service Personnel
Protective equipment:
n
Protective gloves
n
Safety shoes
n
Protective eyewear
Requirements:
n The SMAR
TPOWER
TM
RTU Dispenser is correctly assembled and installed.
Ä
Chapter 5 ‘Assembly and connection’ on page 26
1. Open shut-off valve on water supply pipe.
2. Check that all hoses, connections and components are tight.
3.
In the SMARTPOWER
TM
RTU Dispenser, insert a suitable SMARTPOWER
TM
detergent capsule.
Make sure the labels on the product and the dispenser match.
The colour and shape of the detergent capsule correspond to the product
symbol on the hinged cover
.
4. Close the sink drain.
1
2
Fig. 6: Remove product
1
Press
2
Turn to the right
5.
Press the release button
1
.
If more cleaning solution is required, the release button can be locked in
place by pressing and turning to the right
2
.
Commissioning / operation
33 MAN054128 Ver. 01-06.2024