Chapter 4
| System Management Commands
Banner Information
– 126 –
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure mux command
interprets spaces as data input boundaries. The use of underscores ( _ ) or other
unobtrusive non-letter characters is suggested for situations where white space is
necessary for clarity.
Example
Console(config)#banner configure mux telco-8734212kx_PVC-1/23
Console(config)#
banner configure note This command is used to configure the note displayed in the banner. Use the no
form to restore the default setting.
Syntax
banner configure note note-info
no banner configure note
note-info - Miscellaneous information that does not fit the other banner
categories, or any other information of importance to users of the switch
CLI. (Maximum length: 150 characters)
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure note command
interprets spaces as data input boundaries. The use of underscores ( _ ) or other
unobtrusive non-letter characters is suggested for situations where white space is
necessary for clarity.
Example
Console(config)#banner configure note !!!!!ROUTINE_MAINTENANCE_firmware-
upgrade_0100-0500_GMT-0500_20071022!!!!!_20min_network_impact_expected
Console(config)#