EasyManuals Logo

Edge-Core ECS4620-28P User Manual

Edge-Core ECS4620-28P
1260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Chapter 4
| System Management Commands
System Status
– 134 –
Example
Refer to the example for the running configuration file.
Related Commands
show running-config (131)
show system This command displays system information.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Example
Console#show system
System Description : ECS4620-28T
System OID String : 1.3.6.1.4.1.259.10.1.41.104
System Information
System Up Time : 0 days, 0 hours, 15 minutes, and 38.27 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 70-72-CF-83-34-66
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
System Fan:
Force Fan Speed Full : Disabled
Unit 1
Fan 1: Ok Fan 2: Ok
System Temperature:
Unit 1
Temperature 1: 42 degrees
Main Power Status : Up
Redundant Power Status : Not present
Console#
Table 12: show system – display description
Parameter Description
System Description Brief description of device type.
System OID String MIB II object ID for switch’s network management subsystem.
System Up Time Length of time the management agent has been up.
System Name Name assigned to the switch system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS4620-28P and is the answer not in the manual?

Edge-Core ECS4620-28P Specifications

General IconGeneral
BrandEdge-Core
ModelECS4620-28P
CategorySwitch
LanguageEnglish

Related product manuals