Chapter 27
| OAM Commands
– 863 –
Command Usage
â—† Critical events are vendor-specific and may include various failures, such as
abnormal voltage fluctuations, out-of-range temperature detected, fan failure,
CRC error in flash memory, insufficient memory, or other hardware faults.
â—† Dying gasp events are caused by an unrecoverable failure, such as a power
failure or device reset.
Note:
When system power fails, the switch will always send a dying gasp trap
message prior to power down.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam critical-link-event dying-gasp
Console(config-if)#
efm oam
link-monitor frame
This command enables reporting of errored frame link events. Use the no form to
disable this function.
Syntax
[no] efm oam link-monitor frame
Default Setting
Enabled
Command Mode
Interface Configuration
Command Usage
â—† An errored frame is a frame in which one or more bits are errored.
â—† If this feature is enabled and an errored frame link event occurs, the local OAM
entity (this switch) sends an Event Notification OAMPDU.
Example
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame
Console(config-if)#