PMC-2 Instruction Manual
Page 16 BA * PMC-2 * EN * 01/98
2.6.3 Variable menu
20 V variables (V0 to V19) can be edited with EPAS-3. Display text, lower limit, upper limit and format
are set in parameter group 6.
The variables must be inputted in a row with no gap, because all following variables after format
0.0 are ignored.
If the input is to be blocked, the lower limit must be higher than the upper limit.
Variables are not taken over until format contains a number > 0.0.
If a variable is inserted or deleted, it is not taken over until after RESET at the PMC-2.
If the display text, a limit or the format of an existing variable is changed, this is taken over after
enable LOW -> HIGH (standard parameter takeover).
Example:
Parameter Variable Display text Lower limit Upper limit Format
P 6.00 V0000 Velocity 0 100 3.0
P 6.01 V0001 Laying width 0 10000 5.3
P 6.02 V0002 0 0 0.0
P 6.03 V0003 0 0 0.0
P 6.04 V0004 0 0 0.0
P 6.05 V0005 0 0 0.0
P 6.06 V0006 0 0 0.0
P 6.07 V0007 0 0 0.0
P 6.08 V0008 0 0 0.0
P 6.09 V0009 0 0 0.0
P 6.10 V0010 0 0 0.0
P 6.11 V0011 0 0 0.0
P 6.12 V0012 0 0 0.0
P 6.13 V0013 0 0 0.0
P 6.14 V0014 0 0 0.0
P 6.15 V0015 0 0 0.0
P 6.16 V0016 0 0 0.0
P 6.17 V0017 0 0 0.0
P 6.18 V0018 0 0 0.0
P 6.19 V0019 0 0 0.0
Note:
Format 5.3 means that the number has altogether 5 digits, of which 3 after the decimal point.
Laying width 3.200
Velocity 20
Working line is the lower line.
The variable value is flashing.
Note:
In case of large number formats and long texts, it may happen that the number overwrites the
variable text from the right end.
CAUTION
If the number to be displayed is larger than the format set, the highest digits
are displayed.