EasyManua.ls Logo

ELAU PMC-2 - 10 Technical Data

Default Icon
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PMC-2 Instruction Manual
Page 80 BA * PMC-2 * EN * 01/98
10 Technical data
10.1 PMC-2
general data
Input mains
Nominal a.c. voltage 3 x 360 ... 460V (400V -10%/+15%)
Mains frequency 48 ... 62 Hz
Control voltage
22 ... 33V DC/2A (supply of logics)
Standard inputs
Input voltage/power 20 ... 33V DC/5mA
Input filter standard 5ms
I-filter interrupt input 0.1ms
Motor protection PTC or switch
Resolver 2-channel resolver
Standard outputs
Digital outputs 20 ... 33V DC/0.1A
Relay outputs 60V DC/0.2A
2 monitor outputs
use
regulator adjustment, commissioning and diagnosis
output voltage
+/- 10V
output power
max. 3mA
tolerance
±2%
resolution
12 bit
updating time
1.3 msec
system variables
MON1 -> S3.08
MON2 -> S3.09
Communication
Standard 2 RS 232/485 with SINEC L1
Option field bus interface via option module
Pluggable option modules
max. number 4 pieces
X11 FLB-1
X12 encoder SCI-1, IKA-1 or INK-1
X13 communication IBS-2 or DPS-1
X14 analog I/O ANA-1
Operation conditions
Ambient temperature with
nominal data + 5°C to + 45°C
Storage temperature - 20°C to + 70°C
Air humidity Class F according to DIN 40040
System of protection IP20