PMC-2 Instruction Manual
Page 80 BA * PMC-2 * EN * 01/98
10 Technical data
10.1 PMC-2
general data
Input mains
Nominal a.c. voltage 3 x 360 ... 460V (400V -10%/+15%)
Mains frequency 48 ... 62 Hz
Control voltage
22 ... 33V DC/2A (supply of logics)
Standard inputs
Input voltage/power 20 ... 33V DC/5mA
Input filter standard 5ms
I-filter interrupt input 0.1ms
Motor protection PTC or switch
Resolver 2-channel resolver
Standard outputs
Digital outputs 20 ... 33V DC/0.1A
Relay outputs 60V DC/0.2A
2 monitor outputs
• use
regulator adjustment, commissioning and diagnosis
• output voltage
+/- 10V
• output power
max. 3mA
• tolerance
±2%
• resolution
12 bit
• updating time
1.3 msec
• system variables
MON1 -> S3.08
MON2 -> S3.09
Communication
Standard 2 RS 232/485 with SINEC L1
Option field bus interface via option module
Pluggable option modules
max. number 4 pieces
X11 FLB-1
X12 encoder SCI-1, IKA-1 or INK-1
X13 communication IBS-2 or DPS-1
X14 analog I/O ANA-1
Operation conditions
Ambient temperature with
nominal data + 5°C to + 45°C
Storage temperature - 20°C to + 70°C
Air humidity Class F according to DIN 40040
System of protection IP20