4.3 Mounting
- Mount the units vertically with the power connections on the top side.
- Only connect one motor to each PMC-2.
WARNING HIGH VOLTAGE!
Disconnect from mains supply, before working
on this equipment. Electric discharge > 1min
Caution!
When exploiting the maximum brake power, the air outlet
temperature of the PMC-2 can become >100°C.
- Leave a mounting space of 100 mm on the top, the bottom and the front!
- A free air supply to the fan has to be guaranteed!
- External bleeders should have at least 100 mm distance to all adjacent parts, since they can warm
up very greatly; better is an installation outside the electric cabinet.
ACHTUNG hohe Temperatur
warning high temperature
Oberfläche des Gerätes im Betriebszustand
nicht berühren
do not touch to this surface
under operation conditions