Instruction Manual PMC-2
BA * PMC-2 * EN * 01/98 Page 71
8.6.6 System variables group 5
Number
S
Designation Unit Data type Access level Min-Max
5.00 I_SYN_counter I32 Foreman 1,..,32767
5.01 I_SYN_denomin I32 Foreman 1,...,32767
5.02 I_SYN_offset Unit I32 Foreman
±99999.999
5.03 I_SYN_period Unit I32 Foreman 0,...,999999.999
5.04 I_SYN_end Unit I32 Foreman
±999999.999
5.05 O_SYN_vel Unit/sec I32 Nobody
±99999.9
5.06 O_Counter_0 I32 Nobody 0,..,99999
5.07 O_Denomin_0 I32 Nobody 0,..,99999
5.08 O_Counter_1 I32 Nobody 0,..,99999
5.09 O_Denomin_1 I32 Nobody 0,..,99999
5.10 O_Counter_2 I32 Nobody 0,..,99999
5.11 O_Denominator_2 I32 Nobody 0,..,99999
5.12 I_VEL_OLeit Unit/sec I32 Foreman
±9999.999
5.13 I_VEL_OLage Unit/sec I32 Foreman 0.01 - 99999.99
5.14 I_Master_Filter I32 Foreman 0 – 10
5.15 I_SYN_Stop_Pos Unit I32 Foreman
±999999.999
5.16 I_SYN_SA_Period Unit I32 Foreman 0,...,99999.999
5.17 A_EG_State I32 Nobody 0 - 99
5.18 O_POS_OMaster Unit I32 Nobody
±999999.999
5.19 O_SYN_end_count I32 Nobody 0 - 255
5.20 O_SYN_LA_period Unit I32 Nobody 0,...,999999.999
5.21 O_SYN_FA_period Unit I32 Nobody 0,...,999999.999
8.6.7 System variables group 6 - memory module
Number
S
Designation Unit Data type Access level Min-Max
6.00 O_MEM_contents_0 Text Nobody
6.01 O_MEM_contents_1 Text Nobody
6.02 O_MEM_contents_2 Text Nobody
6.03 O_MEM_contents_3 Text Nobody
6.04 O_MEM_contents_4 Text Nobody
6.05 O_MEM_contents_5 Text Nobody
6.06 O_MEM_contents_6 Text Nobody
6.07 O_MEM_contents_7 Text Nobody