PMC-2 Instruction Manual
Page 24 BA * PMC-2 * EN * 01/98
4 Installation notes
This instruction manual gives you the most important basic requirements for the commissioning of the
PMC-2 positioning motor controller.
However, before you start with the commissioning, there are some instructions to be observed.
4.1 Protection method
CAUTION
For the protection of the unit (especially from metallic powder deposit, oil,
humidity and strong electromagnetic interference as well as for the observance
of the admissible ambient temperature) a system of protection corresponding
to the ambient application has to be guaranteed by the mounting.
With the installation you have to pay attention to the following rules so as to
exclude as far as possible consequences of excessive interference effects.
4.2 ESD protective measures
CAUTION
Electro static discharge becomes a danger with the increasing miniaturisation
for the large-scaled components used, if no protective measures are made
during the handling.
Electrostatically endangered components and assembly groups will
be furnished with the sticker shown here (or similar).
Therefore:
- do not touch components in a way that you have contact with component pins or strip contactors
- do wear a special wrist ribbon when exchanging components
- do lay components on a conducting earthed padding
- do only transport the PMC-2 in an appropriate packaging (original packaging)