BA * PMC-2 * EN * 01/98 Page 65
8.4 Chart with error reactions
Action Error class 1 2 3 4 5
Mains separation
The relay_output "Mains on" (normally-open contact) opens
yes yes no no no
High level disactivated
no EMK braking
yes yes no no no
Brake active
The relay_output "brake release" (normally-open contact) opens
yes yes no no no
Indirect short circuit
The external discharging resistor, decelerated by P16
(time_DC_short circuit), switched via intermediate circuit.
The relay_output "DC short circuit" (normally-open contact)
opens
yes yes no no no
Ready for operation
The output "Ready for operation" opens
off on on on on
Disturbance output
The relay output "Error" (normally-closed contact) opens
on on on on off
Warning output
The relay output "Warning" (normally-closed contact) opens
on on on on on
Drive immediate stop yes yes yes no no
Stop at record end x x no yes no
Acknowledgeable via acknowledge key no yes yes yes yes
ECL stop yes yes no no no
ECL PLC - PT stop no no no no no
Reset outputs (P0.28 Auto_cfg = 00000000 yes yes no no no