BA * PMC-2 * EN * 01/98 Page 89
Instructions for the CE-certification of the appliance family PMC-2
Mains connection
Mains connection is to be done in accordance with the instruction manual, chapter 3 „mounting and
installation instructions“.
ELAU SB-motor
Earth the ELAU SB-motor on the machine via motor enclosure.
ELAU motor cable
On the motor side the motor cable shield is connected to the motor casing via the casing of the power
connector. On the appliance side the shield of the motor cable is to be connected on a large surface
to the casing of the appliance. Use the cable fixing on the top of the appliance.
CAUTION
No additional measures are required for cable lengths up to 10m. For motor
cable lenghts longer than 10m, additional interference suppression measures
are necessary (mains filter, motor filter).
ELAU resolver cable
With the ELAU resolver cable, the shield connection on the motor side is done via a contact of the
resolver cable. On the PMC-2 the shield is connected to the casing via metal case of the D-sub-
connector.
other interfaces (COM, INK, SSI, ...)
For all other interfaces see the instructions in accordance with the chapter 4 Instruction Manual
„Interfaces“.