17 DIAGNOSTICS SYSTEM
17.1 Accessing diagnostics
Z3 Z6
1. Set the selector dial to position 0 (zero).
2. Press the START/PAUSE button and the nearest option button simultaneously (as shown in
the figure).
3. Holding down the buttons, switch the appliance on by turning the programme selector one
position clockwise.
4. Hold the buttons down until the LEDs start to flash (at least 2 seconds).
In the first position, the operation of the buttons and the related LEDs is checked; turning the
programme selector dial clockwise runs the diagnostic cycle for the operation of the various
components and reads any alarms.
17.2 Quitting the diagnostics system
To exit the diagnostics system, turn the selector dial to position 0, turn the appliance back on and return the
dial to position 0.
If “ELE (electricity trials) appears on the screen when you turn the appliance on, repeat the operation of
turning it on and off.